Incinerator
Anton Boiler provides medical waste incinerators, animal waste incinerators and customized waste incineration systems with batch capacity from 20 kg to 1000 kg. Our incinerator systems can be configured with primary chamber, secondary chamber, burner, control cabinet, wet scrubber, dust collector and chimney according to waste type, emission requirements and project site conditions.
Medical Waste Incinerator
Animal Waste Incinerator
Waste Incinerator Solutions for Different Applications
Anton Boiler provides customized incinerator systems for medical waste, animal waste, domestic waste and industrial waste treatment projects.
According to waste type, daily treatment capacity, emission requirements and installation conditions, we can recommend suitable incinerator structure, combustion system, secondary chamber, wet scrubber, dust collector, chimney and control system.
Products: Medical waste incinerator, animal waste incinerator and customized waste incineration system
Batch Capacity: 20–1000 kg/batch
Operating Batches: 8–15 batches per day
Fuel: Diesel, natural gas, LPG
Smoke Residence Time: More than 2 seconds
Ash Residue: Less than 5%
Noise: ≤82 dBA at 1 meter
System: Primary chamber, secondary chamber, burner, control cabinet, wet scrubber, dust collector and chimney
Applications: Hospital, clinic, farm, slaughterhouse, waste treatment plant and industrial waste treatment
Technical Parameters
| Item | Specification |
|---|---|
| Product Type | Medical waste incinerator, animal waste incinerator and customized waste incineration system |
| Batch Capacity | 20 kg/batch, 30 kg/batch, 50 kg/batch, 100 kg/batch, 150 kg/batch, 200 kg/batch, 300 kg/batch, 500 kg/batch, 1000 kg/batch |
| Operating Batches | 8–15 batches per day, depending on waste type, loading condition and operation schedule |
| Fuel Type | Diesel, natural gas, LPG or customized fuel system |
| Combustion System | Primary chamber and secondary combustion chamber |
| Smoke Residence Time | More than 2 seconds |
| Ash Residue | Less than 5% |
| Noise | ≤82 dBA at 1 meter |
| Emission Control | Wet scrubber, dust collector, chimney and auxiliary flue gas treatment system |
| Control System | Automatic control cabinet according to incinerator configuration |
| System Configuration | Incinerator body, burner, control cabinet, wet scrubber, dust collector, chimney and auxiliary equipment |
| Application | Hospital, clinic, farm, slaughterhouse, waste treatment plant and industrial waste treatment |
Scope of Supply
Anton Boiler can provide a complete incinerator system according to project requirements, including incinerator body, primary chamber, secondary chamber, burner, control cabinet, wet scrubber, dust collector, chimney, valves, instruments and auxiliary equipment.
Incinerator Body
Main incinerator body designed according to waste type, treatment capacity, combustion temperature and project requirements.
Primary Chamber
Primary combustion chamber for waste loading, ignition, combustion and initial waste treatment process.
Secondary Chamber
Secondary combustion chamber supports high-temperature flue gas treatment and more complete combustion.
Burner System
Diesel, gas or LPG burner system can be configured according to fuel availability and combustion requirements.
Control Cabinet
Automatic control cabinet for burner control, temperature control, operation monitoring and system safety protection.
Wet Scrubber & Chimney
Wet scrubber, dust collector, chimney and flue gas treatment system can be supplied according to emission requirements.
Applications
Incinerator systems are widely used in medical waste treatment, animal waste treatment, waste management and industrial waste disposal projects. Anton Boiler can recommend suitable incinerator configuration according to waste characteristics, treatment capacity, fuel type, emission requirements and site conditions.
Hospital Waste Treatment
Incineration system for hospitals, clinics and medical waste treatment stations.
Animal Carcass Treatment
Animal waste incinerator for farms, slaughterhouses and livestock disease control projects.
Clinic & Laboratory Waste
Waste incineration solution for clinics, laboratories and small medical waste treatment projects.
Farm Waste Disposal
Incinerator system for poultry farms, livestock farms and animal waste disposal projects.
Waste Treatment Plant
Customized incinerator system for waste treatment plants and local waste management projects.
Municipal Solid Waste Treatment
Customized incinerator system for municipal solid waste, community waste, island waste and local waste management projects.
Why Choose Anton Boiler for Incinerator?
Anton Boiler provides customized incinerator solutions according to waste type, treatment capacity, fuel condition, emission requirements and installation site conditions. Our team can help customers design suitable incineration systems with auxiliary flue gas treatment equipment.
Customized Incineration System
Incinerator structure, chamber size, burner system and auxiliary equipment can be customized according to waste type and capacity.
Complete Flue Gas Treatment
Wet scrubber, dust collector, chimney and auxiliary flue gas treatment system can be supplied according to project requirements.
Multiple Applications
Suitable for medical waste, animal waste, farm waste, clinic waste, municipal solid waste and local waste treatment projects.
Technical Support
Anton Boiler provides technical documents, operation guidance, spare parts and after-sales support for incinerator projects.
Need an Incinerator Solution?
Send us your waste type, daily treatment capacity, fuel type, emission requirements and installation country. Anton Boiler will provide a suitable incinerator system solution and quotation for your project.